SuperTest 3000 Dry Immunofluorescence Analyzer
SuperTest3000 Dry Immunofluorescence Analyzer
Fast, accurate, high sensitivity, strong sample compatibility, wide application scenario
SuperTest 3000 Dry Immunofluorescence Analyzer is a time-resolved immunofluorescence detection system based on the principle of photoelectric detection. The analyzer is capable ofperformingfast quantitative and qualitative tests on common drugs in biological samples including hair, so as to complete the fast screening of suspicious drug users by multiple means.
Features
◆ Fast detection of drugs inbiological samples such as hair, blood, sweat, blood stain, urine, saliva, etc.
◆ Especially sensitive to morphine, methamphetamineandketamine,the detection limit is as low as 0.001ng/mg.
◆ Fast quantitative testing of trace drugconcentrationin sewage.
◆ Fast qualitative testing of trace residues in drug contact media.
Easy Pre-treatment
Ultrasonic extraction of hair sample takes only 5 minutes, other samples can be directly added dropwise or diluted with extracts.
Fast Detection
The drug content in the sample is detected within 5 minutes after sampling. It can directly give the negative or positive interpretation results.
High Precision
Adopts advanced technology, the minimum detection limit of methamphetamine, morphine and ketamine is 0.001ng/mg, and only 5mg of hair samples (about 10*5cm hairs) are needed for testing.
Strong Compatibility
Compatible with the fast qualitative drug detection to samples including hair, blood, dried blood spots, sweat, saliva, urine and other biological samples, and can also quickly quantify the concentration of sewage drugs and rapidly detect the trace residues in drug contact media.
High Integration
SuperTest 3000 is equipped with a built-in thermal printer, and the user can print the test results on the spot immediately after the test is completed.
Complete Set of Supporting Equipment
Weiyun provides urine, saliva and other colloidal gold quick test paper, quick test boxes, Raman spectroscopy equipment, drug fast-testing vehicles and a series of reagents and equipment needed for anti-drug work.
Testing Parameters
Detection Items |
Quantitative Detection Limit (ng/mg) |
InspectionSpecification |
Methamphetamine |
0.2 |
Regulations of the Ministry of Public Security on "Specification for Testing Hair Samples of Drug-Related Personnel": Article 9 The content threshold of O6-monoacetylmorphine, morphine, methamphetamine, amphetamine, 3,4-methylenedioxy amphetamine (MDA), 3,4-methylenedioxymethamphetamine (MDMA), ketamine, norketamine and methcathinone in hair samples is 0.2 ng/mg; the detection content threshold of cocaine is 0.5 ng/mg; the detection content threshold of benzoylecgonine and tetrahydrocannabinol is 0.05 ng/mg. If the actual detected content value is above the threshold, the test result is deemed to be positive. |
Morphine |
0.2 |
|
Ketamine |
0.2 |
Product Configuration
No. |
Name |
Quantity |
Unit |
1 |
Dry Immunofluorescence Analyzer |
1 |
Set |
2 |
Power Adapter |
1 |
Set |
3 |
IDCard |
1 |
Piece |
4 |
Quality Control Card |
1 |
Piece |
5 |
Printing Paper |
1 |
Roll |
6 |
Compact Disc |
1 |
Piece |
7 |
Scanning Gun (optional) |
1 |
Set |
Please feel free to contact us via info@weiyunbio.com